VeriFone VX 520 Specifications Page 63

  • Download
  • Add to my manuals
  • Print
  • Page
    / 190
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 62
VERIX TERMINAL MANAGER
Verix Terminal Manager Menus
VX 520 R
EFERENCE GUIDE 63
5> DIAGS 3 > ICC DIAGS
VoyLib 03.06 0000
VxOS11 PSCR Build 04
SCRLIB 2.B 2/10
1> SMART CARD DIAG
2> LIST SYNC DRIVERS
3> EXIT
When you select 3, the software library version
appears. Choose
1> SMART CARD DIAG to run
diagnostics on the Smart Card reader. Select
2> LIST
SYNC DRIVERS
to view the drivers. Select 3> EXIT to
return to the
VERIX DIAGS MGR screen, or press or
.
5> DIAGS 4 > KEYBOARD DIAG
TERMINAL MGR KBD TEST
KEYCODE nn
This screen displays the hexadecimal ASCII keycode
for each key you press. The value displayed
corresponds to the actual key pressed. Other values
assigned to keys are software dependent.
To test the keyboard, press some keys and check that
they match their keycodes (for example, the 1 key
displays keycode 31). For more hexadecimal ASCII
keycodes, refer to the ASCII table in Appendix C.
For information about the keypress scan codes, see
Keypress Scan Codes.
To stop the test and return to the
VERIX DIAGS MGR
screen, press either or .
5> DIAGS 5 > MAG CARD DIAG
VERIX TERMINAL MGR
TRK 1:VALID DATA
TRK 2:VALID DATA
TRK 3:VALID DATA
To test the magnetic-stripe card reader, swipe a
magnetic-stripe card through it.
A successful test displays
VALID DATA for each track
that reads valid data. An error generates one of the
following error messages for each track with an error:
NO DATA
NO START
NO END
LRC ERR
PARITY ERR
REVERSE END
For more information about magnetic card error
messages, refer to the Verix V Operating System
Programmers Manual (VPN 23230).
To stop the test and return to the
VERIX DIAGS MGR
screen, press .